Emergency Escape
People requiring assistance in order to escape are not restricted to those who are wheelchair users or those whose mobility is otherwise impaired. The evacuation needs of older people, blind and partially sighted people, hearing impaired people and people with language and learning difficulties also need to be considered. It is necessary therefore to make provision for this both in the design of a building and in the way it is managed.
- Older people may need extra time or assistance
- Blind and partially sighted people may require assistance in learning the emergency evacuation routes or assistance in proceeding down exit stairs
- Hearing impaired people may require modification to the standard audible alarms
- Cognitively impaired people may become confused when challenged with the unusual activity during an emergency, lose their sense of direction or may require having emergency directions broken down into simplified steps
The extent to which the building owner/managers will need to implement this assistance will vary with the type of building, its use, its users and location. In multi-storey buildings, for example, the fundamental strategy for evacuating disabled and older people usually involves two stages:
- movement initally to a place of temporary safety (a refuge), followed by
- assisted escape to the outside of the building

Structural measures and other features to be considered
Horizontal escape
Horizontal travel routes must be free from obstacles, such as steps or raised thresholds, which delay or impede travel in emergency escape. Where such obstacles occur, a ramp and steps with handrails should be provided. Notices or contrasting floor finishes are required to provide a warning of any level changes.
Vertical escape
Evacuation lifts
An evacuation lift must:
- have the same fire resistance as a protected stairway
- be clearly marked and signposted as such
- have two independent power supplies
- have controls that can be isolated
- have any electrical boards, generators, hydraulic pumps protected by a fire-resisting enclosure
In larger premises, where possible, one or more lifts should be protected and designated as evacuation lifts for use by disabled people in the event of an emergency escape. Landings at evacuation lifts must be in refuges and within fire resistant walls and doors.

Stairs and ramps
Stair lifts and platform lifts should not be used as a means of escape.
The width of the escape stairway must be equal to the minimum required width for means of escape plus the width of any stair lift.
The maximum height of a stair-riser on upward escape stairs is 180mm.
Evacuation stairs must be between 1000mm and 1400mm wide between handrails.
The standard requirements for ramps, steps and stairs must be met, eg. step nosings should be colour contrasted and handrails should be a contrasting colour to the walls. Tactile thresholds are recommended at the top of flights of stairs.
Handrails, which should be continuous, on escape stairs and ramps should mark the direction of escape with an arrow on the top face. At the final storey the handrail should have "Exit" marked on its surface or on the wall close to the handrail.
Handrails that are placed on both sides of stairs are used as body supports to aid balance and movement, in particular by people with limited or no use of one arm.
Refuges
For people unable to use stairs without assistance, one or more refuge points must be provided on all storeys affected to allow disabled people a place of safety until assistance arrives. The use of refuges is not ideal and evacuation lifts should be provided wherever possible. It can be extremely distressing for disabled and older people to wait in a refuge area during a fire or bomb alert.

A refuge area must be a minimum of 1400mm x 900mm and surrounded by a fire-resisting construction and provide a direct route to the storey exit. They should be clearly indicated by appropriate fire safety signs.
Refuges should be positioned:
- on all floors, except ground floor, one refuge per staircase (and/or per evacuation lift)
- inside a compartment or protected lobby/staircase/stairway
- in open areas such as balconies, flat roof or podium that have their own means of escape away from the risk
Refuges should not be positioned:
- where they would adversely affect the means of escape
- on ground or final exit storeys
- in storeys used for plant only
Refuges need not be positioned in storeys with a floor area of less than 280 square metres in buildings which have only basement, ground and first floors in one occupancy.
A refuge point must be provided with an evacuation chair, eg. a Type A chair to British standard BS 5568. Evacuation chairs are now available which can be operated safely by one person. An appropriate evacuation aid must be provided to assist evacuation from a lower/basement level.

In some cases, eg. existing buildings, it may not be possible to provide an indoor refuge area, in these cases an external refuge may be used, so long as it is protected from fire and smoke escaping from the building. Generally, when providing external refuges, provision of a weather shelter canopy should be considered as should providing shelter at assembly areas.
Fire/evacuation alarm signals and lighting
Alarm systems should incorporate the use of flashing lights or paging/vibrating units to alert hearing impaired people. The latter are emergency alert systems which use radio transmitters to activate miniature receivers worn by deaf people. The receivers vibrate to attract attention and display messages. Such systems can provide safer, cost effective cover at larger public buildings and complexes.
Audible alarms should have a variable tone so that people with a loss of hearing in one part of the sound spectrum do not miss the alarm.
Powered way guidance lighting systems help partially sighted people when leaving buildings in an emergency, in addition to conventional overhead lighting.

Doors
Fire and smoke doors along escape routes should be 'rated'. They are generally rated at 30 minute fire resistance. Where a building is in use by people with disabilities and/or older people, the rate could be set higher eg. 60 or 120 minutes.
Escape route doors should open with crash bars and in the direction of escape.

Communications
Communication must be suitable for people with hearing and speech impairments. At the minimum, a flashing light should indicate that the evacuation co-ordinator has taken notice of their signal.
Sound guidance systems
Larger premises should consider providing sound beacons as they can be advantageous to people who are blind, have learning difficulties and those with a loss of hearing.
Emergency equipment
Fire extinguishers and other emergency equipment needs to be located where people with disabilities can easily reach and operate the equipment.
Fire extinguishers should be sited no more than 1200mm above floor level. If heavier types are provided these should have their base no higher than 650mm above the floor. Raising the extinguisher makes it easier for people with mobility impairments.
Acknowledgement
The above information was collected from the following sources:
- Merseytravel (2006) Code of Practice on Access and Mobility. [accessed 24/10/07].
- The Construction Information Service (2005) Management of emergencies for people with disabilities - a guide for building managers. Croft Consultants. [accessed 26/10/07].

Legislation
- BS 5588-8:1999 - Fire precautions in the design, construction and use of buildings. Code of practice for means of escape for disabled people
- BS DD 9999: 2005 - Code of practice for fire safety in the design, construction and use of buildings
- Building Regulations 2000: Fire Safety - Approved Document (Part B) Volume 2 - Buildings Other Than Dwellinghouses
- ISO/AWI TR 22411 Ergonomic data and guidelines for the application of ISO/IEC Guide 71 in standards related to products and services to address the needs of older persons and persons with disabilities.
Further information:
- Barker, P. Barrick, J. & Wilson, R. (1995) Building Sight - How the needs of blind and partially sighted people can be met in the design of buildings and the environment. London: RNIB. [accessed 16/10/07].
- Bright, K. Flanagan, S. Embleton, J. Selbekk, L. & Cook, G. (2004) Buildings for all to use - improving the accessibility of public buildings and environments. London: CIRIA. [accessed 16/10/07].
- Chartered Institute of Building Services Engineers (2004) Emergency Lighting Design Guide. [accessed 24/10/07].
- Centre for Accessible Environments (2005) Specifiers' Handbooks for Inclusive Design Series [accessed 08/10/07].
- EuCAN (European Concept for Accessibility Network) (2003) The European Concept For Accessibility. [accessed 16/10/07].
- JMU Access Partnership (n.d.) Buildings and Internal Environments. London: RNIB.
- Lacey, A. (2004) Designing for Accessibility. London: Centre for Accessible Environments. [accessed 08/10/07].
- Miller, J. (2003) Fire Safety and Means of Escape for Disabled People. In: Bright K. Disability: Making Buildings Accessible - Special Report. Workplace Law Group. [accessed 24/10/07].
- Sport England (2002) Access for Disabled People. [accessed 16/10/07].
Other information:
- Casserley, C. (2000) Tourism and the DDA: your guide to understanding the Disability Discrimination Act. London: RNIB.
- Communities and Local Governement (2003) Planning and access for disabled people: a good practice guide. [accessed 16/10/07].
- Department for Transport (2005) Inclusive Mobility. [accessed 16/10/07].
- Equality and Human Rights Commission (2001) FOCUS 7: Creating an Inclusive Environment.
- Equality and Human Rights Commission (2004) Making access to goods and services easier for disabled customers - A practical guide for small businesses and other small service providers. [accessed 24/10/07].
- Equality and Human Rights Commission (2005) The Duty to Promote Disability Equality - Statutory Code of Practice.
- Equality and Human Rights Commission (2006) Code of Practice - Rights of Access: services to the public, public authority functions, private clubs and premises. [accessed 16/10/07].
- Human Rights and Equal Opportunity Commission (2007 ) The good, the bad and the ugly – design and construction for access. [accessed 16/10/07].
- National Council for the Blind of Ireland (2005) Guidelines for Accessibility of the Built Environment. [accessed 25/10/07].
- National Disability Authority (2002) Building for Everyone. [accessed 16/10/07].
- RNIB (2000) Welcoming your visually impaired customers, leisure industry pack. [accessed 16/10/07].
- RNIB (2003) The Talking Images Guide - Museums, galleries and heritage sites: improving access for blind and partially sighted people.
- Secretariat for the Convention on the Rights of Persons with Disabilities [n.d.] Accessibility for the Disabled - A Design Manual for a Barrier Free Environment. [accessed 16/10/07].
- VisitBritain (2004) National Accessible Scheme. [accessed 16/10/07].
Picture acknowledgements
- Disability Rights Commission
- Seton (a division of Brady Corporation Ltd)
- United States Access Board - Courthouse Access Advisory Committee
- Garaventa Accessibility
- United States Access Board - Courthouse Access Advisory Committee
- University of Southern California - Career and Protective Services
- Disability Rights Commission
| Back |
Last updated: 19.02.2008 © Copyright reserved